Order Code: LM4801-DR-01

Applications: Industrial Water Boiling and Cooling, Water and Wastewater, Laundry and Sanitation

This kit tests for Total Dissolved Solids using the Direct Reading Titrator method. Range and sensitivity is 0-2000 ppm/20 ppm CaCO3.

The procedure involves 2 acid-base titrations. The first is a direct titration of the negative ions. The second is a titration of positive ions after all positive ions have been exchanged for hydrogen in an ion exchange column. The sum of the titration results equals ppm TDS as CaCO3.

Specifications

Code Test System Range/Sensitivity # Tests (# Rgts) Ship Code
LM4801-DR-01 Direct Reading Titrator 0-2000 ppm/20 ppm CaCO3 50 at 2000 ppm (3) HA (1)

Instructions

Total Dissolved Solids Test Kit Instructions

SDS

Total Dissolved Solids Test Kit SDS

METHYL ORANGE INDICATOR 2299.PDF
HYDROCHLORIC ACID, 0.2N 2818.PDF
SODIUM HYDROXIDE, 0.2N 5168.PDF